구버전 HPACUCLI 명령어
1. 컨트롤러 확인
# hpacucli
=> ctrl all show status
Smart Array 6400 in Slot 6
Controller Status : OK
Cache Status : Disbled
Battery Status : OK
2. 어레이 확인
=> ctrl slot=6 array all show
Smart Array 6400 in Slot 6
array A <Parallel SCSI, Unused Space: ??? MB>
array B <Parallel SCSI, Unused Space: ??? MB>
array C <Parallel SCSI, Unused Space: ??? MB>
3**. 물리 디스크 확인**
=> ctrl slot=6 pd all show
Smart Array 6400 in Slot 6
array A
physicaldrive 1:0 <port 1:id 0 , Parallel SCSI, 72.8 GB, OK>
physicaldrive 1:1 <port 1:id 1 , Parallel SCSI, 72.8 GB, OK>
array B
physicaldrive 1:2 <port 1:id 2 , Parallel SCSI, 300 GB, OK>
physicaldrive 1:3 <port 1:id 3 , Parallel SCSI, 300 GB, OK>
physicaldrive 1:4 <port 1:id 4 , Parallel SCSI, 300 GB, OK>
physicaldrive 1:5 <port 1:id 5 , Parallel SCSI, 300 GB, OK>
array C
physicaldrive 2:0 <port 2:id 0 , Parallel SCSI, 300 GB, OK>
physicaldrive 2:1 <port 2:id 1 , Parallel SCSI, 300 GB, OK>
physicaldrive 2:2 <port 2:id 2 , Parallel SCSI, 300 GB, OK>
physicaldrive 2:3 <port 2:id 3 , Parallel SCSI, 300 GB, OK>
physicaldrive 2:4 <port 2:id 4 , Parallel SCSI, 0 Byte, Failed>
physicaldrive 2:5 <port 2:id 5 , Parallel SCSI, 300 GB, OK>
4**. 논리 디스크 확인**
=> ctrl slot=6 ld all show
Smart Array 6400 in Slot 6
array A
logicaldrive 1 <67.8 GB, RAID 1, OK>
array B
logicaldrive 2 <838 GB, RAID 5, OK>
array C
logicaldrive 3 <1.36 TB, RAID 5, Interim Recovery Mode>